APC APC NETSHELTER RACK PDU APDU11450SW

APC NETSHELTER RACK PDU ADVANCED SWITCHED 34.6KW 3PH 415
Tillverkare: APC
Artikelnr: CO94887D
Tillverkarens artikelnummer: APDU11450SW
EAN: 0731304752806
Leverera till
*
*
Leveranssätt
Namn
Beräknad leverans
Pris
Inga leveransalternativ
Lagerstatus: Ej i lager
Prel. åter i lager: Obekräftat
67 159,00 kr
decrease increase

Produktbeskrivning


APC NetShelter Rack PDU Advanced (11K Series) provides reliable power distribution to IT equipment within server and/or networking racks. Switched outlets allow for turning outlets on or off remotely. PDU level power metering provides power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparalleled deployment flexibility. Maximum outlet density with 42 outlets in a 2.2 in. (5.6 cm) wide form factor allows for more equipment in the rack. Outlets on the PDUs are color coded and labeled by breaker. Live Swap the NMC3 to minimize downtime in the unlikely event of an NMC power event. The rack PDU integrates with EcoStruxure IT through an NMC3 and can be accessed and configured via web, SNMP, and command line interface (CLI). A 10-foot (3-meter) input cord makes it easier for the PDU to reach the power supply. Rated to operate up to 60 C (140 F) at full load ensures reliability and availability even in today's high-density deployments. One gigabit Ethernet/network port (10/100/1000) enhances and standardizes network connectivity. Two link ports are available to cascade to up to 32 PDUs, with a network port sharing (NPS) feature to enable power sharing between Rack PDUs in the cascading group. Track or bill power usage confidently with 1% metering accuracy. Two environmental sensor ports allow for optional sensors (sold separately) to be connected. For data center deployments across multiple regions, these PDUs have the following certifications: UL, CE, CSA, UKCA, Nemiko, PSE, KC, China RoHS, RCM, and CMIM. This model’s input power cord is IEC-309 60 A 3P+N+PE and features 21 count C13/C15/C19/C21 combo outlets and 21 count C13/C15 outlets.


 

Viktiga egenskaper


APC NetShelter Rack PDU Advanced Gen 2, Switched, 34.6kW, 3Phase, 43.5kW 400V 63A or 34.6kW 415V 60A, 560P6, 42 Outlet. PDU types: Metered, Rack capacity: 0U, Type: Three-phase. AC outlets quantity: 42 AC outlet(s), AC outlet types: C13 coupler, C15 coupler, C19 coupler, C21 coupler. Management platform: NMC3. Nominal input voltage: 400 V, Maximum current: 60 A, AC input frequency: 50/60 Hz. Compliance certificates: RoHS


 

Teknisk specifikation


Design

PDU typesMetered
TypeThree-phase
Rack capacity0U
Product colourBlack

Ports & interfaces

AC outlets quantity42 AC outlet(s)
AC outlet typesC13 coupler,C15 coupler,C19 coupler,C21 coupler
Ethernet LAN (RJ-45) ports5
USB ports quantity1

Management features

Management platformNMC3

Power

Nominal input voltage400 V
AC input frequency50/60 Hz
Maximum current60 A
Nominal output voltage400 V
Load capacity34600 VA
Number of phases3

Weight & dimensions

Width56 mm
Depth75 mm
Height1826 mm
Weight11700 g

Packaging data

Package weight17000 g
Package width132 mm
Package depth262 mm
Package height2110 mm

Technical details

Compliance certificatesRoHS