APC Switched Rack PDU 2G Zero U

APC Switched Rack PDU 2G Zero U - Kraftdistributionsenhet (kan monteras i rack) - AC 200/208/230 V - Ethernet 10/100, RS-232 - ingång: NEMA L6-30 - utgångskontakter: 24 - 0U - svart - för P/N: SMX1000C, SMX1500RM2UC, SMX1500RM2UCNC, SMX750C, SMX750CNC, SR
Tillverkare: APC
Artikelnr: 2973268A
Tillverkarens artikelnummer: AP8641
EAN: 731304276975
Leverera till
*
*
Leveranssätt
Namn
Beräknad leverans
Pris
Inga leveransalternativ
Lagerstatus: Ej i lager
Prel. åter i lager: 2025-05-19
24 105,00 kr
decrease increase

Produktbeskrivning


Metered-by-outlet Rack PDUs provide real-time remote monitoring of each individual outlet to empower IT professionals with the necessary tools for advanced data center energy management.

APC by Schneider Electric Metered by Outlet with Switching Rack Power Distribution Units (PDUs) enable advanced, user-customizable power control and individual outlet power metering. Remote outlet level controls allow power on/off functionality for power recycling to reboot locked-up equipment and to avoid unauthorized use of individual outlets. Power sequencing delays allow users to define the order in which to power up or down attached equipment. Avoid circuit overload during power recovery and extend uptime of critical equipment by prioritizing the load shedding. Current metering provides real-time remote monitoring of connected loads. Switched Rack PDUs include real power monitoring, a temperature/humidity sensor port, and locking IEC receptacles.

User-defined alarms warn of potential circuit overloads before critical IT failures occur. Users can access, configure, and control Switched Rack PDUs through secure Web, SNMP, Command Line Interface, or Telnet Interfaces which are complimented by Schneider Electric's StruxureWare solution.

Metering-by-Outlet capability: Individual outlet level power metering provides a more granular view of the power distributed to equipment within the enclosure. It also provides the ability to analyze component power trends and perform capacity planning.

Metering-by-Outlet capability - Individual outlet level power metering provides a more granular view of the power distributed to equipment within the enclosure. It also provides the ability to analyze component power trends and perform capacity planning.

Network Management - Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.

Remote Individual Outlet Control - Remotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).

Alarm Thresholds - Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems. (Note: Only available on units with the current monitoring capabilities.).

Local Current Monitoring Display - The aggregate current draw per power distribution unit is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip. (Available on designated SKUs only).

Power Delays - Allows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly.

Load Indicator LED - Indicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits.

Flash Upgradeable - Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only).


 

Egenskaper


Network Management
Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.

Remote individual outlet control
Remotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).

Power delays
Allows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly.

Load indicator LED
Indicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits.

Integrates with InfraStruXure Central
An IT-ready, scalable monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network.

Single input power source
Supply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.


 

Teknisk specifikation


Allmänt
Typ av enhetKraftdistributionsenhet - kan monteras i rack
Höjd (U-format)0U
FärgSvart
LokaliseringJapan, Kanada, Förenta Staterna
Nätdel
InspänningAC 200/208/230 V
Inspänningens områdeAC 200-240 V
Erforderlig frekvens50/60 Hz
Inmatningsanslutningar1 x ström, NEMA L6-30
Kontaktdetaljer för uteffekt3 x ström IEC 60320 C19
21 x power IEC 60320 C13
UtspänningAC 200/208 V
Max elektrisk ström24 A
Nätverk
Gränssnitt för fjärradministrationEthernet 10/100, RS-232
Protokoll för administration på distansSNMP, Telnet, HTTP
Expansion/Anslutning
Gränssnitt1 x hantering (Ethernet) - RJ-45
1 x hantering (RS-232)
Diverse
Medföljande kablarStrömkabel - extern - 3 m
Seriell kabel - extern
RackmonteringssatsInkluderat
EgenskaperHörbart larm, LCD-bildskärm, överbelastningsskydd
Standarder som följsUL, cUL, ICES-003, VCCI klass A ITE, RoHS, FCC Part 15 A, REACH
Tillverkarens garanti
Service och supportBegränsad garanti - 2 år
Miljöparametrar
Min temperatur vid drift-5 °C
Max temperatur vid drift45 °C
Luftfuktighet vid drift5 - 95%
Mått och vikt
Bredd5.6 cm
Djup5.1 cm
Höjd183 cm
Vikt8.2 kg
Mått och vikt (brutto)
Emballagets bredd16.2 cm
Emballagets djup11.8 cm
Emballagets höjd204 cm
Emballagets vikt10.5 kg
Kompatibilitetsinformation
Designat förP/N: AP4431, AP7950B, AR2200, AR2280, AR2401, AR2407, AR2480, AR2487, AR2487G, AR2500, AR2507, AR2580, AR2587, AR3100G, AR3100TAA, AR3100W, AR3105SP, AR3105W, AR3107G, AR3107SP, AR3140G, AR3140W, AR3150SP, AR3150W, AR3155SP, AR3155W, AR3157SP, AR3180G, AR3300G, AR3300SP, AR3300W, AR3305SP, AR3305W, AR3307SP, AR3307W, AR3340G, AR3340W, AR3350SP, AR3350W, AR3355SP, AR3355W, AR3357SP, AR3357X674, AR9300SP, AR9300SP-R, AR9307SP, AR9307SP-R, NBES0302, NBPD0160A, NBPD0180, NBWL0355A, NBWL0356A, SMC1000-BR, SMC1000I, SMC1000I-2U, SMC1000I-2UC, SMC1000I-BR, SMC1000IC, SMC15002U-BR, SMC1500-BR, SMC1500I, SMC1500I-2U, SMC1500I2U-BR, SMC1500I-2UC, SMC1500I-BR, SMC1500IC, SMC2000I-2U, SMC3000RMI2U, SMT1500RM1U, SMT1500RM2U, SMT1500RMI1U, SMT2200RM2UC, SMT3000I2U-BR, SMT3000RM2UC, SMX1000C, SMX1000US, SMX1500RM2UC, SMX1500RM2UCNC, SMX1500RMNCUS, SMX1500RMUS, SMX2000LV, SMX2000LVNC, SMX2000LVNCUS, SMX2000LVUS, SMX2200HV, SMX2200HVNC, SMX2200R2HVNC, SMX2200RMHV2U, SMX2200RMLVUS, SMX3000HV, SMX3000HV-BR, SMX3000HVNC, SMX3000HVT, SMX3000HVTUS, SMX3000LV, SMX3000LV2U-BR, SMX3000LVNC, SMX3000LVNCUS, SMX3000LVUS, SMX3000RMLVUS, SMX3KRMLVNCUS, SMX750C, SMX750CNC, SMX750-NMC, SMX750US, SRT1000RMXLA, SRT1000RMXLA-NC, SRT1000RMXLI, SRT10KRMXLI, SRT10KRMXLT, SRT10KRMXLT-10KTF, SRT10KRMXLT30, SRT10KRMXLT-5KTF2, SRT10KXLT, SRT10KXLT30, SRT10KXLT-5KTF2, SRT10KXLTUS, SRT10KXLTW, SRT10RMXLIX806, SRT1500RMXLA, SRT1500RMXLA-NC, SRT3000RMXLT, SRT3000RMXLT-5KTF, SRT3000RMXLT-NC, SRT3000XLT, SRT3000XLT-5KTF, SRT3000XLTW, SRT5KRMXLT, SRT5KRMXLT-5KTF, SRT5KRMXLT-IEC, SRT5KRMXLTUS, SRT5KRMXLW-HW, SRT5KRMXLW-TW, SRT5KXLJ, SRT5KXLT, SRT5KXLT-5KTF, SRT5KXLTUS, SRT6KRMXLI, SRT6KRMXLT, SRT6KRMXLT-5KTF, SRT6KRMXLT-IEC, SRT6KXLT, SRT6KXLT-5KTF, SRT6KXLTUS, SRT6KXLTW, SRT8KRMXLI, SRT8KRMXLT, SRT8KRMXLT30, SRT8KRMXLT-5KTF, SRT8KRMXLT-IEC, SRT8KXLJ, SRT8KXLT, SRT8KXLT30, SRT8KXLT-5KTF, SRT8KXLT-IEC, SRT8KXLTUS, SURT3000XLI-ET, SURT5000XLIX438, SYAF16KRMICH